| GENERAL SPECIFICATIONS |
| DXS-54 | |
|---|---|
| Power: | one 9V alkaline battery (supplied) |
| Current Consumption: | 15 mA transmitting, 4 mA walk test, 8 µA standby, 15 µA timer mode |
| Battery Life: | Three years (typical) |
| Battery Saver Timer: | 4-minute software timer, rearms after alarm transmission |
| Measured Range: | 1,500 feet open air, with DVS 2400 control panel |
| Accessories: | Mounting hardware, including screws, double-stick tape |
| Code Outputs: | Alarm, supervisory, and low battery |
| Detector: | Balance dual element, pyroelectric |
| Installed Lens: | Standard Fresnel lens, 24 facets, 9 main, 8 intermediate, 5 short, 2 creep |
| Detection Pattern: | 30 feet x 30 feet |
| PIR Sensitivity: | Preset, non-adjustable, pulse count of 3 with 8-second detection window |
| Operating Frequency: | 315 MHz |
| Dimensions: | 3.2" W x 4.4" H x 1.75" D (81 x 44 x 112 mm) |
Specifications subject to change without notice.